Call for Paper, 10 April 2026. Please submit your manuscript via online system or email at editor@ijew.io

ISSN E 2409-2770
ISSN P 2521-2419

MEMS-Based Biosensor Design and Microfabrication for Tear Glucose Sensing


Fahad Riaz , Longbing Heb, Shaikh Sabieh


Vol. 13, Issue 03, PP. 22-38, March 2026

DOI

Keywords: Smart contact lens; MEMS biosensor; Tear glucose monitoring; Wireless power transfer

Download PDF


Continuous glucose monitoring using smart contact lenses offers a promising non-invasive alternative for diabetes management; however, reliable wireless power delivery and integration of rigid microelectronic components into soft contact lens substrates remain significant engineering challenges. This study presents a battery-free smart contact lens platform integrating MEMS biosensors with a wireless power transfer (WPT) system for real-time tear glucose monitoring. The system employs a near-field communication (NFC) inductive coupling architecture operating at 13.56 MHz, incorporating a miniaturized microcoil embedded within a transparent SU-8/PDMS composite to maintain optical clarity and biocompatibility. A peripheral active-zone integration strategy places electronic components outside the optical region, ensuring unobstructed vision while maximizing power transfer efficiency. The power management module integrates a multi-stage rectifier and a high-efficiency buck–boost converter fabricated on a flexible polyimide substrate, achieving conversion efficiencies exceeding 95%. Experimental evaluation demonstrates a wireless power transfer efficiency of 31.4%, delivering a stable continuous power supply of 30–35 mW suitable for sustained biosensor operation and wireless telemetry. A supercapacitor-based energy buffering system further stabilizes transient load variations during data transmission. To enable reliable integration on curved substrates, a sacrificial-layer flattening technique and compliance-based stress mitigation framework were developed, ensuring mechanical reliability and long-term lens comfort. The proposed architecture establishes a scalable wireless power and integration framework for next-generation wearable biosensing platforms, enabling clinically deployable smart contact lenses for continuous, non-invasive glucose monitoring in diabetic patients.


  1. Fahad Riaz, fahad310798@outlook.com, School of Integrated Circuits, Southeast University, Wuxi, 214000, China.
  2. Longbing He, helongbing@seu.edu.cn, School of Electronics Science and Engineering, Southeast University, Nanjing, 210096, China.
  3. Shaikh Sabieh , shaikhsabieh@outlook.com, School of Integrated Circuits, Southeast University, Wuxi, 214000, China.

Fahad Riaz Longbing Heb Shaikh Sabieh “MEMS-Based Biosensor Design and Microfabrication for Tear Glucose Sensing Vol. 13 Issue 03 PP. 22-38 March 2026. https://doi.org/10.5281/zenodo.19124891.


[1]   J. P. McCulley and W. D. Mathers, “Structure and function of the lacrimal secretory system,” in Ocular Surface Disease: Cornea, Conjunctiva and Tear Film, Elsevier, 2013, pp. 38–51.

[2]   B. V. Norm and J. L. Foulks, “The tear film,” in Dry Eye Disease: The Clinician’s Guide to Diagnosis and Treatment, Thieme, 2015, pp. 12–34.

[3]   M. Y. Su, J. Z. Ma, H. Zhang, and W. C. Knudtson, “A comparison of tear glucose levels in diabetic and non-diabetic subjects,” Investigative Ophthalmology and Visual Science, vol. 43, no. 12, pp. 3714–3719, 2002.

[4]   S. Kallenborn-Gerhardt, A. J. Schilling, P. Atanasov, and J. Kruth, “Non-invasive glucose monitoring using tear glucose sensors,” Diabetes Technology and Therapeutics, vol. 19, no. 3, pp. 180–191, 2017.

[5]   J. Y. Lee, J. K. Park, and S. J. Park, “Tear glucose measurement for non-invasive diabetes monitoring,” Journal of Biomedical Optics, vol. 20, no. 4, p. 047001, 2015.

[6]   Yildirim, A. Atanasov, J. Gonzales, and R. Bhatia, “Correlation between tear glucose and blood glucose in diabetic patients,” American Journal of Ophthalmology, vol. 167, pp. 35–41, 2016.

[7]   R. Markert, U. Staub, and S. Frey, “Temporal dynamics of tear glucose in response to blood glucose changes,” IEEE Transactions on Biomedical Engineering, vol. 68, no. 2, pp. 459–467, 2021.

[8]   M. Bao, Y. Gong, X. Zhou, and L. Li, “Real-time kinetic analysis of tear-blood glucose relationship,” Biosensors and Bioelectronics, vol. 165, p. 112413, 2020.

[9]   K. C. Park, S. H. Lee, and J. W. Kim, “First-order kinetic modeling of tear glucose response to blood glucose excursions,” Journal of Diabetes Research, vol. 2021, p. 8837416, 2021.

[10]           M. Parviz, “Augmented reality in a contact lens,” IEEE Spectrum, vol. 46, no. 9, pp. 30–35, 2009.